Origin, validation and certification

SpeedAge was born in a geriatrics department, was validated in real clinical practice and is CE marked.

Albacete General HospitalPrototype designed and tested in the Geriatrics Department, with real patients.
2020Validation published in Health Policy and Technology.
TodayInstalled in hospitals, pharmacies and clinics in Spain and Portugal.

Born in a geriatrics department

SpeedAge was not designed in an engineering lab. The prototype was developed in the Geriatrics Department of Albacete General Hospital, in response to an everyday clinical need: measuring gait speed quickly, accurately and always in the same way.

Its inventors are Gunnar M. Andersen, Héctor Caulín Roldán and Dr Pedro Abizanda Soler, a geriatrician at the hospital and professor at the University of Castilla-La Mancha, with a long track record in frailty and functional assessment of older adults.

Validated in real clinical practice

The system was compared with the GAITRite reference standard and with stopwatch-timed SPPB gait speed in a Falls Unit, and was then used in more than 5,000 outpatients with no technical measurement errors.

Health Policy and Technology · 2020 · 9(1): 102–108

Validation of a self-implemented Walkway system for gait speed measurement in usual clinical care

Abizanda P, Venegas LC, Andersen GM, Caulín Roldán H, López Utiel M, Esbrí Víctor M. Geriatrics Department, Albacete General Hospital.

90Falls Unit patients in the validation
5,328outpatients in routine use
0.81–0.82correlation with GAITRite and SPPB (p < 0.001)
0.02 m/smean difference versus SPPB (Bland-Altman)

Authors’ conclusion: a valid, easy-to-use, self-implemented device for measuring gait speed in routine clinical practice with older people.

Read the article (DOI 10.1016/j.hlpt.2019.11.006)

Same population, almost identical mean speed

Mean gait speed in the 90 patients, by method (m/s)

CE CE markedApproved by the Albacete Research Ethics CommitteeDeclaration of HelsinkiCited in international reviews

Figures from the validation study

Original charts from the published article, reproduced with their citation. They show how SpeedAge agrees with the SPPB stopwatch and with the GAITRite reference system.

Scatter plots of the speed measured with SpeedAge versus the SPPB (left) and versus GAITRite on the second walk (right)
Agreement with reference methods. Speed measured with SpeedAge (vertical axis) versus the SPPB stopwatch (left) and versus GAITRite, second walk (right), in 90 patients. R² = 0.676 and 0.678.Source: Fig. 2 (A, B) from Abizanda P, Venegas LC, Andersen GM, Caulín Roldán H, López Utiel M, Esbrí Víctor M. Validation of a self-implemented Walkway system for gait speed measurement in usual clinical care. Health Policy and Technology. 2020;9(1):102–108. doi:10.1016/j.hlpt.2019.11.006
Bland-Altman plots of the differences between SpeedAge and SPPB (left) and between SpeedAge and GAITRite (right)
Agreement between methods (Bland-Altman). Mean difference of 0.02 m/s versus the SPPB and −0.11 m/s versus the second GAITRite walk. The lines show the mean difference and the 95% limits of agreement.Source: Fig. 2 (C, D) from Abizanda P, Venegas LC, Andersen GM, Caulín Roldán H, López Utiel M, Esbrí Víctor M. Validation of a self-implemented Walkway system for gait speed measurement in usual clinical care. Health Policy and Technology. 2020;9(1):102–108. doi:10.1016/j.hlpt.2019.11.006
Histogram of gait speed in the outpatient measurements taken with SpeedAge
Real-world clinical use. Distribution of gait speed in the 5,328 outpatients measured with the system between June 2017 and June 2018. Mean speed: 0.65 m/s.Source: Abizanda P, Venegas LC, Andersen GM, Caulín Roldán H, López Utiel M, Esbrí Víctor M. Validation of a self-implemented Walkway system for gait speed measurement in usual clinical care. Health Policy and Technology. 2020;9(1):102–108. doi:10.1016/j.hlpt.2019.11.006

How to read these figures

In the scatter plots, the more closely the points cluster around the diagonal, the more similar the two measurements are. In the Bland-Altman plots, each point is a patient: the central line is the mean difference between methods and the outer lines contain 95% of the differences.

The histogram shows the system working in everyday clinics: thousands of measurements with no technical errors, with most patients below 0.8 m/s, the frailty cut-off.